1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV-KABEL
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV-KABEL
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV-KABEL
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV-KABEL
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV-KABEL
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV-KABEL
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV-KABEL
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV-KABEL
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV-KABEL
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV-KABEL
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV-KABEL
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV-KABEL

1 / 5

1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV-KABEL

Ontvang de meest recente Prijs
Stuur een aanvraag
Model No. : YJY62
Brand Name : HUAYUAN YONGTONG
Type : Insulated
Conductor Type : Stranded
Application : Underground
Conductor Material : Copper
Sheath Material : Crosslinking
Insulation Material : XLPE
Material Shape : Round Wire
Certification : ISO9001
Brand : HUAYUAN YONGTONG
meer
8yrs

Beijing, Beijing, China

Bezoek de winkel
  • Platformcertificering
  • Video

Product beschrijving

1. APPLICALBE NORMEN

De kabel die door Beijing Huayuan wordt aangeboden, moet als volgt worden ontworpen, vervaardigd en getest volgens de internationale normen:

Quality Control Standard

ISO 9001

Quality Management Systems

ISO 14001

Environmental Management Systems

Component Material Standard

IEC 60228

Conductors of insulated cables

Cable Standard

IEC 60502-2

Power cables with extruded insulation and their  accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) –

Part 2:Cables for rated voltages from 6 kV (Um = 7,2 kV)

up to 30 kV (Um = 36 kV)


2.CABLES STRUCTUUR voor 1C * 400mm2 kabel

cable1



CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV 1 × 400/35 mm2

Construction

Nominal Thickness(mm)

Nominal Diameter(mm)

1- Stranded compacted circular copper conductor

/

23.2

2- Conductor screen

0.8

24.8

3- XLPE insulation

8.0

40.8

4- Insulation screen

0.6

42.0

5- Semi-conductive water-blocking tape

0.3

42.3

6- Copper wire with copper tape screen

Nominal cross section 35mm2

44.6

7- Wrapping tape

0.2

45.2

8- PVC inner sheath

1.5

48.2

9- Aluminum wire armour

2.5

53.2

10-Wrapping tape

0.25

54.7

11-PVC Outer sheath

2.8

60.3


3. Gegarandeerde technische bijzonderheden

N2XSYRY

18/30 KV Power Cable- CU/XLPE/SCRlBDlAWAlPVC

Size 1x400 Sqmm

Size 1x400 Sqmm





Item

Description

Specification

offer

1

No. ofCores

1

1

2

Conductor Material

Cu

Cu

3

Conductor size

400 mm²

400 mm²(nominal)

4

No. And diameter of wires (No/mm)

61x2.85

60x2.97(nominal)

5

Conductor Diameter

~22.5 mm

23.2mm(nominal)

6

Thickness of inner semi-conductor layer

~ 0.8 mm

0.8mm(nominal)

7

Diameter over inner semi-conductor layer

~22 mm

24.8mm(nominal)

8

Insulation material

XLPE

XLPE

9

THickness of insulation, nominal

~6 mm

8.0mm(nominal)

10

Diameter over insulation,nominal

~33 mm

40.8mm(nominal)

11

Thickness of outer semi-conductor layer

~0.5 mm

0.6mm(nominal)

12

Diameter  of outer semi-conductor layer

35 mm

42.0mm(nominal)

13

Semi-conductor & water blocking tape thickness

0.3 mm

0.3mm(nominal)

14

Nominal crosssection of screen

35 mm²

35 mm²

15

Screen specification

Copper wire &copper tape applied helically

Copper wire &copper tape applied helically

16

Specification sheath material

PVC (ST2)

PVC (ST2)

17

Thickness of separation sheet

~ 40 mm

1.5mm(nominal)

18

Diameter of armour wires

Alumininum & 2.5 mm

2.5(nominal,AL wire)

19

Diameter of over amouring

 ~ 44 mm

53.2(nominal)

20

Outer sheet material

PVC (ST2)

PVC (ST2)

21

Thickness of outer sheath, nominal

2.5 mm

2.8 mm(nominal)

22

Overal diameter

~50 mm

60.3(nominal)

23

AC test voltage for 5 min (For fisrt time)

70 KV

70 kV

24

Cable color

Red

red


4.TEST EISEN VOOR MV Stroomkabels

De kabeltests moeten worden uitgevoerd in overeenstemming met de toepasselijke norm van 18 / 30kV voedingskabels. De volgende testitems moeten worden uitgevoerd in overeenstemming met de relevante IEC-normen.

No.

Test item

Routine tests

1

measurement of the electrical resistance of conductors

2

Partial discharge test

3

Voltage test

Sample tests

1

conductor examination

2

check of dimensions

3

Voltage test for 4 h

4

Hot set test for XLPE insulation



Ons bedrijf

Factory-1


werkplaats


undefined

Pakket

undefinedundefined

Levering en betaling

undefined

undefined


Eer

undefined

Uur klant

undefined


1. Drie Kern Koperen Geleider 2. Vijf Core Koperen Geleider 3. Hoge Voltage Power Kabel 4. 33 kv Kabel 5. Bouwkabel 6. Staal Draad Gepantserde Kabel 7. Steel Tap eArmoured

Stuur een aanvraag

Productalert

Abonneer u op uw geïnteresseerde zoekwoorden. We sturen de nieuwste en heetste producten vrij naar uw inbox. Mis geen handelsinformatie.